The Call Home Event Notification Setup dialog box is displayed
Figure 31
Call Home Event Notification Setup dialog box
3.
Select the Enable Call Home Event Notification check box.
A check mark is displayed in the check box to indicate call-home event notification is enabled.
NOTE:
Element Manager application. Call-home event notification can be active for some Edge
Switches and inactive for others.
4.
Click Send Test.
A call-home test message is sent.
5.
Click OK to close the dialog box.
6.
Maximize the Hardware view.
7.
At the Hardware view, select Enable Call Home Notification from the Maintenance menu.
A check mark is displayed in the check box to indicate call-home event notification for the Edge
Switch is enabled, and the menu closes.

Threshold alerts

A threshold alert notifies you when the transmit (Tx) or receive (Rx) throughput reaches specified
values for specific Edge Switch ports or port types (E_Ports or F_Ports).
You are notified of a threshold alert in four ways:
A yellow triangle is displayed on the port in the Port Card view.
A yellow triangle is displayed on the port in the Hardware view.
A yellow triangle is displayed in the Alert column of the Port List view.
A yellow triangle is displayed by the Threshold Alerts box in the Port Properties dialog box.
Detailed threshold alert data is recorded in the Threshold Alert Log.
The enable function must also be activated for each Edge Switch through the
(Figure
31).