Canon imageRUNNER ADVANCE C255 Series Service Manual page 447

Table of Contents

Advertisement

E614-0301-00
Detection Description
Remedy
E614-0311-00
Detection Description
Remedy
E614-0401-00
Detection Description
Remedy
Flash PCB error
An error was detected in the system area. (Initialization failed at startup or I/O error at startup)
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
[Related parts] R1.00
- Flash PCB (UN91)
- Main Controller PCB (UN81)
[Remedy] Perform the following in the order while checking whether the error is cleared. Although
the error is cleared by "HD-CHECK", it may occur again. Thus, perform Remedies 1 to 4.
1. Check the related harness/cable and connector.
2. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "0", and execute "HD-CHECK". Then,
turn OFF and then ON the main power.
3. Obtain the necessary backup data by referring to the backup data list.
[Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and
"Appendix> Backup Data List" in the Service Manual.
4. Enter safe mode using (2+8) startup, and execute Flash Format using a USB flash drive.
5. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
6. Replace the Main Controller PCB.
Flash PCB error
An error was detected in the system area. (File could not be written in the Flash PCB after startup
or I/O error after startup)
[Related parts] R1.00
- Flash PCB (UN91)
- Main Controller PCB (UN81)
[Remedy] Perform the following in the order while checking whether the error is cleared. Although
the error is cleared by "HD-CHECK", it may occur again. Thus, perform Remedies 1 to 4.
1. Check the related harness/cable and connector.
2. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "0", and execute "HD-CHECK". Then,
turn OFF and then ON the main power.
3. Obtain the necessary backup data by referring to the backup data list.
[Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and
"Appendix> Backup Data List" in the Service Manual.
4. Enter safe mode using (2+8) startup, and execute Flash Format using a USB flash drive.
5. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
6. Replace the Main Controller PCB.
Flash PCB error
Logical partition error was detected. (Initialization failed at startup or I/O error at startup)
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
[Related parts] R1.00
- Flash PCB (UN91)
- Main Controller PCB (UN81)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Obtain the necessary backup data by referring to the backup data list.
[Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and
"Appendix> Backup Data List" in the Service Manual.
2. Enter safe mode using (2+8) startup, and execute Flash Format using a USB flash drive.
3. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
4. Replace the Main Controller PCB.
436
7. Error/Jam/Alarm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner advance c355 series

Table of Contents