Chassis Slot Power Indicators; Chassis Linkup And Activity Indicators - Magma EB7-X8G2 User Manual

Pcie to pcie
Table of Contents

Advertisement

Magma

Chassis Slot Power Indicators

If the unit is in Hot-Plug mode (default factory setting) then the orange Power Off LEDs found between the slots and
chassis will be lit. They indicate lack of power at the respective PCIe slot. This would be a normal condition if the chassis is
powered on while the Host system is turned off (RESET state) or if power to a specific slot has been removed for it to be
swapped as part of the
Hot-Plug
procedure.
If the Host system is turned ON but there is no PCIe card in the slot, the Power Off LED will be ON.
If the unit is NOT in Hot-Plug mode, the orange LED's should be all off.
If a slot has a card in it and the respective orange LED turns on that means there was a power fault in that slot. If that is
the case, one needs to follow appropriate procedure to power down the host and then power down the chassis. If the
problem persists, check with the card manufacturer if it requires more than 8 Amps of current at any time. Otherwise
contact Magma Technical support.

Chassis Linkup and Activity Indicators:

These indicators were purposely made visible at the back of the chassis in order to allow a quick verification of
connectivity between Host and chassis.