Maximum Frame Rate Period Formula - IAI GO-5100M-USB User Manual

5.1m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

■ Maximum frame rate period formula

During continuous operation ([Frame Start] trigger is [Off] or [Exposure Mode] is [Off])
• Maximum frame rate of sensor output
SensorFR = 1 / {Hperiod × (Height + 40)}
• Maximum frame rate by interface
InterfaceFR = 3000 × 1000000 / (Height × Width × Pack value)
• Maximum frame rate
FR_Cont = Min (Sensor FR, Interface FR)
When the exposure time is longer than the frame interval
• Maximum exposure time at maximum frame rate
MaxExposureTime_TrOlrd = (1 / FR_Cont) - (14 × H Period)
• Exposure time outside of frame interval
NonOverlapExposureTime = ExposureTime - MaxExposureTime_TrOlrd
However, NonOverlapExposureTime calculation results that are 0 or below will be considered as 0.
• Maximum frame rate
FR_ContLongExposure = 1/{(1/FR_Cont) + NonOverlapExposureTime}
When [Frame Start] trigger is [On] and [Trigger OverLap] is [Off]
• Maximum frame rate of sensor output
Sensor FR = 1 / {H Period × (Height + 40)}
• Maximum frame rate by interface
Interface FR = 3000 × 1000000 / (Height × Width × Pack value)
• Maximum frame rate
FR_Cont = Min (Sensor FR, Interface FR)
• Exposure time possible within frames
MaxOverlapTime_TrOloff = (1 / FR_Cont) - (1 / Sensor FR)
• Exposure time outside of frame interval
NonOverlapExposureTime_TrOloff = ExposureTime - MaxOverlapTime_TrOloff
However, NonOverlapExposureTime_TrOloff calculation results that are 0 or below will be
considered as 0.
For TriggerWidth, the trigger pulse is equivalent to ExposureTime.
• Maximum frame rate
FR_TrOloff = 1 / {(1 / FR_Cont) + NonOverlapExposureTime_TrOloff}
When [Frame Start] trigger is [On] and [Trigger OverLap] is [Readout]
• Maximum frame rate of sensor
Sensor FR = 1 / {H Period × (Height + 40)}
• Maximum frame rate by interface
Interface FR = 3000 × 1000000 / (Height × Width × Pack value)
• Maximum frame rate
FR_Cont = Min (Sensor FR, Interface FR)
• Exposure time possible within frames
MaxOverlapTime_TrOlrd = (1 / FR_Cont) - (14 × H Period)
• Exposure time outside of frame interval
NonOverlapExposureTime_TrOlrd = ExposureTime - MaxOverlapTime_TrOlrd
However, NonOverlapExposureTime_TrOlrd calculation results that are 0 or below will be considered
as 0.
For TriggerWidth, the trigger pulse is equivalent to ExposureTime.
• Maximum frame rate
FR_TrOlrd = 1 / {(1 / FR_Cont) + NonOverlapExposureTime_TrOlrd}