Configuring Exposure And External Trigger Settings - IAI GO-5100M-USB User Manual

5.1m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Configuring Exposure and External Trigger Settings

Configure settings related to exposure control methods and trigger control.
The factory settings are as follows. Change settings as necessary, according to the intended purpose
or application.
Factory default values
Trigger Selector (trigger operation)
Trigger Mode
Trigger Source (trigger signal source)
Trigger Activation (trigger polarity)
Exposure Mode
Exposure Time
Exposure Auto*
* This item is only enabled when [Exposure Mode] is set to [Timed].
Caution
When [Exposure Mode] is set to [Off], [Trigger Mode] cannot be set to [On]. Other settings may also be restricted
depending on the exposure mode, so be sure to set the exposure mode before configuring the trigger settings.
■ Control via External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Trigger Selector (trigger operation)
Trigger Mode
Trigger Source (trigger signal source)
Trigger Activation (trigger polarity)
Exposure Mode
Exposure Time
Exposure Auto
* 1 The minimum value will differ depending on the [Pixel Format] setting value.
™ The actual exposure time will consist of the image sensor's offset duration (13.7 μs) added to the
setting configured on the camera.
When [ExposureMode] is set to [Timed] and the exposure time is set to 7 μs, the actual exposure
time will be as follows.
7 μs + 13.7 μs (offset duration of image sensor) = 20.7 μs
When [ExposureMode] is set to [TriggerWidth], the exposure is slightly longer than the width of the
trigger signal. To achieve an exposure time of 20.7 µs and the exposure time offset is 13.7 µs, use
20.7 µs - 13.7 µs = 7 µs as the high or low time for the trigger signal.
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
Item
Item
— 17 —
Default value
Frame Start
Off
Line 5 - Optical In 1
Rising Edge (rising edge of input signal)
Timed (control via exposure time)
13427 (µs)
Off
Setting value / selectable range
Frame Start
On
Any
Rising Edge (rising edge of input signal), Falling Edge (falling
edge of input signal)
Timed (control via exposure time)
8 bit: 7 to 7999920(µs)* 1
10/12 bit: 8 to 7999900(µs)* 1
Off, Continuous
GO-5100M-USB / GO-5100C-USB