When [Exposure Mode] Is [Trigger Width]; During Normal Continuous Operation (Both [Exposure Mode] And [Trigger Mode] Disabled) - IAI GO-2401M-PGE User Manual

2.35m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

■ When [Exposure Mode] is [Trigger Width]

Example: When [Trigger Source] is set to [Line 5 - Optical In 1] and [OptIn Filter Selector] is set to
[10 µs]
Scanning range
Full
ROI 2/3 (Height = 810)
ROI 1/2 (Height = 608)
ROI 1/4 (Height = 304)
ROI 1/8 (Height = 152)
Binning Vertical 2*
* GO-2401M-PGE only
Exposure and readout cannot overlap on the GO-2401-PGE. The above table indicates the shortest trigger
periods for the shortest exposure times. By adding the value of the exposure time you are using to the
values in the table, you can determine the shortest trigger periods under your own environment.
Trigger
CMOS exposure
Exposure active
FVAL
8-/10-bit packed
10-bit

■ During normal continuous operation (both [Exposure Mode] and [Trigger Mode] disabled)

When using an application that does not require external triggers, the shortest repetition period will be
as follows.
Scanning range
Full
ROI 2/3 (Height = 810)
ROI 1/2 (Height = 608)
ROI 1/4 (Height = 304)
ROI 1/8 (Height = 152)
Binning Vertical 2*
* GO-2401M-PGE only
Shortest period of trigger
8-/10-bit
30.782 ms
30.782 ms
30.782 ms
30.782 ms
30.782 ms
30.782 ms
t1
t2
Exposure duration
t1
t2
72.7 µs
80.0 µs
Shortest period
8-/10-bit
30.782 ms
30.782 ms
30.782 ms
30.782 ms
30.782 ms
30.782 ms
— 29 —
GO-2401M-PGE / GO-2401C-PGE
Next trigger disabled
t3
t4
t3
t4
80.0 µs
827.8 µs
Next trigger
input enabled
t5
t5
336 µs
10.6 ms

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-2401c-pge

Table of Contents