Relay Group - YOKOGAWA WT110 User Manual

Digital power meter
Table of Contents

Advertisement

Appendix 2.3 Commands

2.3.11 RELay Group

The commands in the RELay group are used to make settings relating to, and inquiries about the comparator function. This
allows you to make the same settings and inquiries as when using the lower menus of [OUTPUT]-"rELAY". This group is only
useful in case your instrument is equipped with the /CMP option.
;
:RELay
:
STAT e
<Space>
MODE
<Space>
NCHannel
HCHannel
DISPlay
<Space>
RELay?
Function
Queries all settings relating to the comparator
function.
Syntax
RELay?
Example
RELAY?→:RELAY:STATE 0;MODE SINGLE;NCHANNEL1:
FUNCTION V,1;THRESHOLD
600.0E+00;:RELAY:NCHANNEL2:
FUNCTION A,1;THRESHOLD
20.00E+00;:RELAY:NCHANNEL3:
FUNCTION W,1;THRESHOLD
1.200E+03;:RELAY:NCHANNEL4:
FUNCTION PF,1;THRESHOLD
1.000E+00;:RELAY:HCHANNEL1:FUNCTION
V,1,1;THRESHOLD
600.0E+00;:RELAY:HCHANNEL2:FUNCTION A,1,1;
THRESHOLD 20.00E+00;:RELAY:HCHANNEL3:
FUNCTION W,1,1;THRESHOLD
1.200E+03;:RELAY:HCHANNEL4:FUNCTION
PF,1;THRESHOLD 1.000E+00;:RELAY:DISPLAY OFF
App2-28
OFF
ON
<NRf>
?
SINGle
DUAL
?
;
:
FUNCtion
<Space>
<x>
THReshold
<Space>
;
:
FUNCtion
<Space>
<x>
THReshold
<Space>
<NRf>
CHANnel
<x>
OFF
?
?
,
<NRf>
<Normal meas. function>
ELEMent
SIGMa
OFF
?
<NRf>
?
?
<Harmonic analysis
,
<NRf>
function>
ELEMent
OFF
?
<NRf>
?
?
RELay:DISPlay
Function
Sets the comparator display OFF, or, in case of ON,
the channel to be displayed/queries the current setting.
Syntax
RELay:DISPlay {<NRf>|CHANnel<1-4>|OFF}
RELay:DISPlay?
{<NRf>}=1 to 4:channel
Example
RELAY:DISPLAY 1
RELAY:DISPLAY?→:RELAY:DISPLAY 1
RELay:HCHannel<x>?
Function
Queries all settings related to relay output items in
case of harmonic analysis.
Syntax
RELay:HCHannel<x>?
<x>= 1 to 4
Example
RELAY:HCHANNEL1?→:RELAY:HCHANNEL1:
FUNCTION V,1,1;
THRESHOLD 600.0E+00
<x>
,
<NRf>
<x>
ORDer
<x>
IM 253401-01E

Advertisement

Table of Contents
loading

This manual is also suitable for: