Operation Keys And Function/Element Display - YOKOGAWA WT110 User Manual

Digital power meter
Table of Contents

Advertisement

2.2

Operation Keys and Function/Element Display

WT110 (253401): Operation keys and function display
Indicators for operation conditions
Shows sampling, voltage/current overrange and
measurement mode
V RANGE
Shows the voltage range setting menu (page 4-4)
A RANGE
Shows the current range setting menu (page 4-4,
4-8)
SHIFT
Switches between modes (page 4-1)
AUTO indicator
Lights up when range is AUTO
FUNCTION
Sets the displayed function (Ch. 5, 6)
Function/unit display
A
SCALING
SAMPLE
AVG
V OVER
FILTER
A OVER
MODE
B
STORE
RMS
RECALL
V MEAN
HARMONICS
DC
hour
C
START
SHIFT HARMONICS
Shows the setting menu for harmonics ON/OFF,
PLL source, and element selection (Ch. 8)
STOP
SHIFT
MEMORY
Shows the setting menu for storing/recalling
measurement data and set-up information (Ch. 9)
LOCAL
When the REMOTE indicator is lit, the remote
function will be canceled. When the REMOTE
indicator is not lit, the setting menu for
communication/printing will appear
LOCAL
SHIFT
INTERFACE
Shows the setting menu for communication/printing
(Ch. 11, 12)
SETUP
SHIFT
OUTPUT
Shows the setting menu for communication output items, D/A
output, plotter /printer output and comparator output (Ch. 10 to
12)
SETUP
For settings such as initializing settings, filter, average, scaling,
computing and ext. sensor input (Ch. 4)
Indicators for operating functions
When a function is set and in operation, this indicator will light up
2-2
V RANGE
MODE
hour
min
m
V
VA
var
k
A
M W
TIME
m
V
PF
k
A
deg
M W
%
min
sec
m
V
Hz
h
k
A
M W
h
HOLD
Keeps the displayed value, and the HOLD
indicator will light up. Pressing once again will
result in canceling HOLD
SHIFT
When in the HOLD situation this results in
updating the displayed value
AUTO
AUTO
FUNCTION
V RANGE A RANGE
HOLD
MODE
TRIG
ENTER
FUNCTION
INTEGRATOR
START
STOP
RESET
HARMONICS MEMORY
INTEG SET
FUNCTION
REMOTE
LOCAL
SETUP
INTERFACE
OUTPUT
SHIFT
HOLD
TRIG
For decreasing the voltage/current range,
and for setting of functions/values
For increasing the voltage/current range,
and for setting of functions/values
ENTER
For verifying the set range/function/value
SHIFT
Moves the cursor of a value from left to right
SHIFT
Moves the decimal point from left to right
START
Starts integration
STOP
Stops integration
RESET
Integration value and elapsed time of
integration are set to zero(0)
RESET
SHIFT
INTEG SET
Shows the setting menu for integration
mode/time, and rated integration time (Ch. 7)
IM 253401-01E