3.4 INSTALLING A NEW DRUM

NOTE:
The installation procedure for a new drum is the same as for the
base copier (A109) except the following steps which come after
turning on the main switch.
The steps from 3 to 12 are to apply lubricant to the new drum
surface. These steps can all be replaced by just making 10
copies of the C-4 Test Chart on A3 (11"X17") paper.
If the developer is replaced together with the OPC drum, steps 3
to 12 are unnecessary because lubricant is applied to the drum
surface during the developer initialization.
1. Replace the OPC drum with a new one and reassemble the copier.
2. Turn on the main switch.
3 . Place a few sheets of A3 (11"X17") white paper and close the platen
cover (DJF).
4 . Enter the SP mode and open [2]SP Test, page 1.
5 . Set the Test Pattern Level [A] to " 30 ".
NOTE: If the test pattern level is too high, a lot of toner will be
consumed and toner scattering will occur inside the machine.
SM
[A]
5-11
A172/A199