7. TRANSFER BELT UNIT

7.1 TRANSFER BELT BIAS

Transfer Belt Bias (Face Side: Normal Humidity)
Dev.
Cycle
Transfer Belt Bias Depending on Humidity Range (1C Mode: Face Side)
Bias
2075
1740
1410
This machine changes the transfer belt bias voltage for every mode and
every copy cycle.
For 1C copy mode, which is more influenced by environmental conditions,
the transfer belt bias output is divided into five ranges by four threshold
values (as mentioned in the table above) and is determined by the output of
the humidity sensor. Only three different bias settings are present as the
factory setting for each environment.
The transfer belt bias voltage data can be monitored in the SP Adjustment
Mode P-5 and 6. These data should not be changed. For more details, see
the SP Mode Section.
A172/A199
1C
1st
1410
2nd
3rd
4th
L o w 1
L o w 2
L o w 3
0
5.5
8.5
2-28
Copy Mode
2C
3C
1410
1410
1410
1490
1490
1490
1575
1575
1660
N o r m a l
High
11.3
21.5
Humidity (g/m
4C
3
)
SM