Tech Service Bulletin No. AFICIO COLOR 5106/5206 - 014
Page 2 of 2
In addition to the regular PM schedule, the following procedure must be performed every 20,000 scans or
5,000 copies. This procedure is mandatory regardless of the percentage of job mix (throughput material &
paper). If the additional maintenance is not performed, fuser damage will occur.
• Replace the oil supply pad P/N AE045015.
• Remove and discard of the silicon oil in accordance will local regulations.
• Replace the oil tank P/N AA031008 or thoroughly clean the oil tank with clean silicon fuser oil and a lint
free cloth.
• Replace the oil blade P/N AE041002
• Clean the hot roller, pressure roller, cleaning roller, oil supply tube, oil pump, stripper fingers and oil
sump with a lint free cloth and clean silicon fuser oil.
• Clean the exit rollers with alcohol or a suitable roller cleaner.
• Add new silicon fuser oil.