15.17 STOPPER SOLENOID REPLACEMENT

[D]
1. Turn off the main switch and remove the upper cover. (Refer to Upper
Cover Removal.)
2. Disconnect the connector [A] of the stopper solenoid.
3. Open the feed-in cover and the original stopper.
4. Remove the bracket [B] with the stopper solenoid (2 screws and 1
E-ring.)
5. Remove the stopper solenoid [C] (2 screws).
NOTE: When installing the stopper solenoid, pay attention to the following
points:
1) The spring [D] must be correctly hooked onto the stopper [E], as
shown.
2) Manually pull the stopper solenoid plunger to confirm that the
press rollers firmly contact the pick-up rollers. When the pick-up
rollers are manually rotated, the press rollers also rotate. If not,
adjust the stopper solenoid position.
SM
[B]
[A]
[C]
[E]
[D]