Developer Installation - Ricoh A172 Service Manual

Hide thumbs Also See for A172:
Table of Contents

Advertisement

4.2 DEVELOPER INSTALLATION

[A]
1. From the Developer Collection procedure step number 9 condition,
remove all the toner supply receptacles [A] (1 screw).
2. Remove the right inner cover. (See A109 Right Inner Cover Removal.)
3. Remove the developer supply funnel [B] from the bracket [C] and clean
the inner surface.
4. Set the developer supply funnel on the black development section as
shown.
5. Open SP Test Mode P-4 (Output Check).
6. Touch the key [D], to enter the output mode.
7. Enter "68" with the number keys, then touch the key [D] again to select
test mode #68 "black development drive motor ON".
8. Touch the Start key [E].
9. Shake a pack of black developer [F] 20 times then pour it in.
10. 1 minute after pouring the developer, touch the stop key [G].
NOTE: Do not touch the stop key within 1 minute, otherwise, the
developer will not be distributed evenly in the development unit.
SM
[F]
[B]
[B]
[D] [E]
5-15
[C]
[G]
A172/A199