Fusing - Ricoh A172 Service Manual

Hide thumbs Also See for A172:
Table of Contents

Advertisement

1.8 FUSING

SC541: Fusing (hot roller) thermistor open
- Definition - [A]
The output of the fusing (hot roller) thermistor goes to 5 V, corresponding
to 0°C.
- Possible causes -
Fusing (hot roller) thermistor open
Fusing unit not installed
Main control board defective
SC542: Fusing (hot roller) warm-up error
- Definition - [A]
The fusing (hot roller) temperature does not reach the ready temperature
within 12 minutes after the main switch is turned on.
- Possible causes -
Fusing (hot roller) thermistor not in position
Fusing (hot roller) lamp open
Fusing (hot roller) thermistor defective
Main control board defective
SC543: Fusing (hot roller) overheat
- Definition - [A]
A fusing (hot roller) temperature of over 200°C is detected 5 times (within
5 seconds).
- Possible causes -
Fusing (hot roller) thermistor defective
AC drive board defective (triac)
Main control board defective
A172/A199
6-18
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

A199