15.8 INVERTER SOLENOID REMOVAL AND ADJUSTMENT

[D]
1. Remove the feed-out unit. (Refer to Feed-out Unit Removal.)
2. Remove the inverter solenoid [A] (2 screws).
NOTE: When installing the inverter solenoid, check the following:
1) The arm [B] must be set on the plunger pin [C].
2) The inverter solenoid connector harness [D] should be facing
the outside of the unit as shown.
3) Manually push the plunger and check that it works smoothly.
4) When the inverter solenoid does not activate (OFF), the
inverter guide [E] must be inside the outer inverter guide [F],
and when the inverter solenoid activates (ON), the inverter
guide must be outside the outer inverter guide, as shown.
A172/A199
[B]
[C]
[A]
ON
OFF
7-36
OFF
[E]
[F]
ON