Page
Item
Transfer Belt
Bias (Back
Side: Normal
Humidity)
1C Mode
Output
Correction
<1>
-6
Humidity Range
Threshold
Transfer Roller
Bias (Normal
Humidity)
<1>
-7
SM
Function
Adjusts the transfer belt bias
voltage for each transfer
process of the back side copy
in the manual duplex mode with
normal humidity.
Adjusts the 1C transfer belt bias
voltage for unusual humidity
ranges.
These are for the back side
copy in the manual duplex
mode.
Sets the threshold of the
humidity ranges for the transfer
belt bias and roller bias.
Adjusts the transfer roller bias
voltage for each transfer
process (1C ∼ 4C) and the
paper modes (Normal, Thick,
OHP: S, OHP: L, Normal: Back,
and Thick: Back).
4-11
Note
Do not adjust in the field.
Default:
1C:
1410
2C:
1490
3C:
1575
4C:
1660
Adjustable range: 50 ~ 4000 V
Do not adjust in the field.
Default:
Low 1: 2075
Low 2: 1740
Low 3: 1740
High:
1410
Do not adjust in the field.
Default:
1: 43
2: 85
3: 113
4: 215
Do not adjust in the field.
Adjustable range: 500 ~ 4000 V
Default:
Normal Paper
1C: 1200
2C: 1500
3C: 1800
4C-L&P: 1500
Thick Paper
1C: 1100
2C: 1360
3C:1640
4C-L&P: 1360
OHP: S&L
1C: 2020
2C: 2080
3C: 2370
4C-L&P: 2080
Normal: Back
1C: 1200
2C: 1700
3C: 1980
4C-L&P: 1700
Thick: Back
1C: 1360
2C: 1640
3C: 1930
4C-L&P: 1640
A172/A199