Advanced Features; Table 11-9 Active Reference - Emerson Digitax ST User Manual

Hide thumbs Also See for Digitax ST:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
installation
11.22

Advanced features

This section gives information on some of the advanced functions of the
drive. For additional information see the Advanced User Guide.
Reference modes
Braking modes
S ramps
Torque modes
Stop modes
Main loss modes
Start/stop logic modes
Position loop modes
Fast disable
11.22.1
Reference modes
1.14
Reference selector
RW
Txt
A1.A2 (0), A1.Pr (2), A2.Pr (2),
Pr (3), PAd (4), Prc (5)

Table 11-9 Active reference

Pr 1.14
Pr 1.15
State
0
0 or 1
1
2 to 8
A1.A2 (0)
0
9 *
1
0
1
0
0
1
A1.Pr (1)
1
2 to 8
9 *
0
1
0
0
1
A2.Pr (2)
1
2 to 8
9 *
0
1
0
0
Pr (3)
1
1 to 8
9 *
PAd (4)
Prc (5)
* Setting Pr 1.15 to 9 enables the Preset reference scan timer. With the
scan timer enabled the preset references are selected automatically in
turn. Pr 1.16 defines the time between each change.
164
Electrical
Getting
Basic
installation
started
parameters
Pr 1.14, Pr 1.15 and Pr 8.39
Pr 2.04 and Pr 2.08
Pr 2.06 and Pr 2.07
Pr 4.08 and Pr 4.11
Pr 6.01 and Pr 6.08
Pr 6.03, Pr 6.48, Pr 4.13 and Pr 4.14
Pr 6.04 and Pr 6.40
Pr 13.10
Pr 6.29
NC
US
A1.A2 (0)
Digital Input T28
Function
State
Local Remote
No function
Local Remote
No function
Preset select bit 0
No function
Preset select bit 0
No function
Preset select bit 0
No function
No function
No function
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
1.15
Preset reference selector
RW
Uni
8.39
T28 and T29 auto-selection disable
RW
Bit
OFF (0) or On (1)
If Pr 8.39 is set to OFF (0), then the setting of Pr 1.14 automatically
changes the operation of digital inputs T28 and T29 by configuring the
destination parameters Pr 8.25 and Pr 8.26. To allow Pr 8.25 and Pr 8.26
to be changed manually by the user, the automatic set-up must be
disabled by setting Pr 8.39 to 1.
If Pr 8.39 is 0 and Pr 1.14 is changed, then a drive reset is required
before the function of terminal T28 or T29 will become active.
Digital Input T29
Function
Jog forward**
0
Preset select bit 1
1
No function
0
Preset select bit 1
1
No function
0
Preset select bit 1
1
No function
No function
No function
** Jog forward can only be selected when the drive is in either the ready
(rdy), inhibit (inh) or trip states.
Onboard
Advanced
Technical
PLC
parameters
Data
NC
0 to 9
Pr 1.49
Pr 1.50
Active Reference
1
1
Analog input 1
2
1
Analog input 2
1 or 2
2 to 8
Preset reference 2 to 8
1
1
Analog input 1
2
1
Analog input 2
1 or 2
2 to 8
Preset reference 2 to 8
1
Analog input 1
2
Preset reference 2
3
Preset reference 3
4
Preset reference 4
1
1
Analog input 1
2 to 8
Preset reference 2 to 8
1
Analog input 1
2 to 8
Preset reference 2 to 8
1
Analog input 2
2
Preset reference 2
3
Preset reference 3
4
Preset reference 4
2
1
Analog input 2
2 to 8
Preset reference 2 to 8
1
Analog input 2
2 to 8
Preset reference 2 to 8
1
Preset reference 1
2
Preset reference 2
3
Preset reference 3
3
4
Preset reference 4
1 to 8
Preset reference 1 to 8
1 to 8
Preset reference 1 to 8
4
Keypad reference
5
Precision reference
Digitax ST User Guide
UL listing
Diagnostics
information
US
0
US
OFF (0)
Issue Number: 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents