Emerson Digitax ST User Manual page 193

Hide thumbs Also See for Digitax ST:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
installation
Trip
SLX.Er
Solutions Module slot X trip: Solutions Module in slot X has detected a fault
SLM module category
Check value in Pr 15/16.50. The following table lists the possible error codes for the SM-SLM. See the Diagnostics section in the
SM-SLM User Guide for more information.
Error Code
0
1
2
3
4
5
6
7
8
202,207,212
9
10
11
12
13
14
15
16
17
18
19
74
SLX.HF
Solutions Module slot X trip: Solutions Module X hardware fault
Ensure Solutions Module is installed correctly
200,205,210
Return Solutions Module to supplier
SLX.nF
Solutions Module slot X trip: Solutions Module has been removed
Ensure Solutions Module is installed correctly
203,208,213
Re-instal Solutions Module
Save parameters and reset drive
SL.rtd
Solutions Module trip: Drive mode has changed and Solutions Module parameter routing is now incorrect
Press reset.
215
If the trip persists, contact the supplier of the drive.
SLX.tO
Solutions Module slot X trip: Solutions Module watchdog timeout
Press reset.
201,206,211
If the trip persists, contact the supplier of the drive.
t010
User trip defined in 2
10
SM-Applications program must be interrogated to find the cause of this trip
t038
User trip defined in 2
38
SM-Applications program must be interrogated to find the cause of this trip
t040 to t089
User trip defined in 2
40 to 89
SM-Applications program must be interrogated to find the cause of this trip
t099
User trip defined in 2
99
SM-Applications program must be interrogated to find the cause of this trip
t101
User trip defined in 2
101
SM-Applications program must be interrogated to find the cause of this trip
t112 to t160
User trip defined in 2
112 to 160
SM-Applications program must be interrogated to find the cause of this trip
Digitax ST User Guide
Issue: 3
Electrical
Getting
Basic
installation
started
parameters
No fault detected
Power supply overloaded
SLM version is too low
DriveLink error
Incorrect switching frequency selected
Feedback source selection incorrect
Encoder error
Motor object number of instances error
Motor object list version error
Performance object number of instances error
Parameter channel error
Drive operating mode incompatible
Error writing to the SLM EEPROM
Motor object type incorrect
Digitax ST object error
Encoder object CRC error
Motor object CRC error
Performance object CRC error
Digitax ST object CRC error
Sequencer timeout
Solutions module over temperature
nd
processor Solutions Module code
nd
processor Solutions Module code
nd
processor Solutions Module code
nd
processor Solutions Module code
nd
processor Solutions Module code
nd
processor Solutions Module code
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
Diagnosis
Trip Description
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
UL listing
information
193

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents