Figure 4-5 Drive Cable Clearances - Emerson Digitax ST User Manual

Hide thumbs Also See for Digitax ST:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
installation
4.10.3
Recommended cable management

Figure 4-5 Drive cable clearances

The external EMC filter can be
bookcase mounted (next to the
drive) or footprint mounted (with
the drive mounted onto the filter).
External
controller
Signal cables
Plan for all signal cables
to be routed at least
300mm (12in) from the
drive and any power cable
28
Electrical
Getting
Basic
installation
started
parameters
Thermal
overload
protection
device
Metal back
plate
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
Optional
braking resistor
Locate optional braking
resistor and overload
external to cubicle
(preferably near to or
on top of the cubicle).
Onboard
Advanced
Technical
PLC
parameters
Data
Note
For EMC compliance:
1) When using an external EMC
filter, one filter is required for
each drive
2) Ensure direct metal contact
at drive and filter mounting
points (any paint must be
removed)
AC supply
contactor and
fuses or MCB
Digitax ST User Guide
UL listing
Diagnostics
information
Issue: 3