Figure 11-35 Sm-I/O 24V Protected Analog Output Logic - Emerson Digitax ST User Manual

Hide thumbs Also See for Digitax ST:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
installation
Figure 11-35 SM-I/O 24V Protected analog output logic diagram
T10 Analog output 1
10
T12 Analog output 2
Input
terminals
Output
terminals
The parameters are all shown at their default settings
SM-I/O 24V Protected parameters
Parameter
x.01
Solutions Module ID
x.02
Solutions Module Main Software Version
x.03
T5 digital I/O 3 state
x.04
T6 digital I/O 4 state
x.05
T7 digital input 5 state
x.06
T8 digital input 6 state
x.07
T9 digital input 7 state
x.08
Relay 1 state
x.09
T3 digital I/O 1 state
x.10
T4 digital I/O 2 state
x.11
T3 digital I/O 1 invert
x.12
T4 digital I/O 2 invert
x.13
T5 digital I/O 3 invert
x.14
T6 digital I/O 4 invert
x.15
T7 digital input 5 invert
x.16
T8 digital input 6 invert
x.17
T9 digital input 7 invert
x.18
Relay 1 invert
x.20
Digital I/O read word
x.21
T3 digital I/O 1 source/destination
x.22
T4 digital I/O 2 source/destination
x.23
T5 digital I/O 3 source/destination
x.24
T6 digital I/O 4 source/destination
x.25
T7 digital input 5 destination
x.26
T8 digital input 6 destination
x.27
T9 digital input 7 destination
x.28
Relay 1 source
x.29
T6 digital I/O 4 output select
x.31
T3 digital I/O 1 output select
x.32
T4 digital I/O 2 output select
x.33
T5 digital I/O 3 output select
x.39
Analog output mode
x.40
Relay 2 state
x.42
Relay 2 invert
x.43
Relay 2 source
x.45
Analog output 2 scaling
x.47
Analog output 2 source
x.48
Analog output 1 source
x.49
Analog output 1 scaling
x.50
Solutions Module error status
x.51
Solutions Module software sub-version
Digitax ST User Guide
Issue Number: 3
Electrical
Getting
Basic
installation
started
parameters
Key
Read-write (RW)
0.XX
parameter
Read-only (RO)
0.XX
parameter
Range( )
0.00 to 99.99
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
OFF (0) or On (1)
0-20, 20-0, 4-20, 20-4
0.0 or 100.0 %
OFF (0) or On (1)
Pr 0.00 to Pr 21.51
0.000 to 4.000
Pr 0.00 to Pr 21.51
Pr 0.00 to Pr 21.51
0.000 to 4.000
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
Default( )
0 to 599
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
OFF (0)
0 to 255
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
OFF (0)
OFF (0)
OFF (0)
OFF (0)
Pr 0.00
Pr 0.00
Pr 0.00
0 to 255
0 to 99
Onboard
Advanced
Technical
PLC
parameters
Data
205
RO
Uni
RO
Uni
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RW
Bit
RO
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
RW
Uni
On (1)
RW
Bit
RW
Bit
RW
Bit
RW
Bit
0-20
RW
Uni
RO
Bit
RW
Bit
RW
Uni
1.000
RW
Uni
RW
Uni
RW
Uni
1.000
RW
Uni
RO
Uni
RO
Uni
UL listing
Diagnostics
information
Type
PT
US
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
NC
PT
US
US
US
US
US
US
US
US
NC
PT
DE
US
DE
US
DE
US
DE
US
DE
US
DE
US
DE
US
US
US
US
US
US
US
NC
PT
US
US
US
US
US
US
NC
PT
NC
PT
149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents