installation
SM-SLM parameters
Parameter
x.01
Solutions Module ID
x.02
Solutions Module software version
x.03
Speed
x.04
Revolution counter
x.05
Position
x.06
Fine position
x.07
Operating mode
x.08
Marker pulse received indicator
x.09
SLM converted flux offset
x.10
Encoder lines per revolution
x.11
SLM software version
x.12
SLM power-up delay
x.13
Not used*
x.14
Sequencer status
x.15
Not used*
x.16
Not used*
x.17
Not used*
x.18
Not used*
x.19
Feedback filter
x.20
Not used*
x.21
Not used*
x.22
Not used*
x.23
Not used*
x.24
Not used*
x.26
Autotune mode
x.27
Saving mode
x.28
Parameters transferred
Action the tuning and saving
x.29
parameters
x.30
Automatic basic drive set-up request
x.32
Not used*
x.33
Not used*
x.34
Not used*
x.35
Not used*
x.36
Not used*
x.37
Not used*
x.38
Not used*
x.39
Not used*
x.40
Not used*
x.41
Not used*
x.42
Not used*
x.43
Not used*
x.44
Not used*
x.45
Axis initialised
x.46
Not used*
x.47
Not used*
x.48
Not used*
x.49
Lock position feedback
x.50
Solutions Module error status**
Solutions Module software sub-
x.51
version
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
* Some of the parameters which are not used will be introduced in scheduled product enhancement.
**See trip SLX.Er, SLM module category on page 193.
158
Electrical
Getting
Basic
installation
started
parameters
Range( )
0 to 499
0.0 to 99.99
±40,000.0 rpm
0 to 65,535 revolutions
16
0 to 65,535 (1/2
ths of a revolution)
32
0 to 65,535 (1/2
nds of a revolution)
HoSt (0), Enc.Only (1)
OFF (0) or On (1)
0 to 65,535
0 to 50,000
0.000 to 9.999
0.000 (0), 0.250 (1), 0.500 (2),
0.750 (3), 1.000 (4), 1.250 (5),
1.500 (6) s
0 to 16
0 (0), 1 (1), 2 (2), 4 (3), 8 (4), 16 (5) ms
0 to 4
0 to 2
0 to 2
OFF (0) or On (1)
0 to 1
OFF (0) or On (1)
OFF (0) or On (1)
0 to 255
0 to 99
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
Default( )
HoSt (0)
OFF (0)
0.000
0.250 (1)
OFF (0)
OFF (0)
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
PLC
parameters
Data
RO
Uni
RO
Uni
RO
Bi
RO
Uni
RO
Uni
RO
Uni
RW
Txt
RO
Bit
0
RO
Uni
1024
RW
Uni
RO
Uni
RW
Txt
RO
Uni
0 (0)
RW
Txt
0
RW
Uni
0
RW
Uni
0
RW
Uni
RW
Bit
0
RW
Uni
RO
Bit
RW
Bit
RO
Uni
RO
Uni
Txt
Text string
US
User save
Digitax ST User Guide
UL listing
Diagnostics
information
Type
PT
US
NC
PT
FI
NC
PT
FI
NC
PT
FI
NC
PT
FI
NC
PT
US
NC
US
NC
PT
US
NC
PT
US
US
US
US
US
US
PT
PT
NC
PT
NC
PT
PS
Power down save
Issue Number: 3