Emerson Digitax ST User Manual page 122

Hide thumbs Also See for Digitax ST:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
installation
Parameter
13.01 Revolutions error
13.02 Position error
13.03 Fine position error
13.04 Position controller reference source
13.05 Position controller feedback source
13.06 Position reference invert
13.07 Ratio numerator
13.08 Ratio denominator
13.09 Position controller P gain
13.10 Position controller mode
13.11 Absolute mode enable
13.12 Position controller speed clamp
13.13 Orientation position reference
13.14 Orientation acceptance window
13.15 Orientation position complete
13.16 Position error reset
13.17 Relative jog reference
13.18 Relative jog enable
13.19 Relative jog reverse
13.20 Local reference turns
13.21 Local reference position
13.22 Local reference fine position
13.23 Local reference disable
13.24 Ignore local reference turns
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
122
Electrical
Getting
Basic
installation
started
parameters
drv (0), Slot1 (1), Slot2 (2), LocAL (4)
drv (0), Slot1 (1), Slot2 (2)
0.00 to 100.00 rad s
Position controller disabled (0)
Rigid position control - feed fwd (1)
Rigid position control (2)
Non-rigid position control - feed fwd (3)
Non-rigid position control (4)
Orientation on stop and when drive enabled (6)
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
Range( )
-32,768 to +32,767
-32,768 to +32,767
-32,768 to +32,767
OFF (0) or On (1)
0.000 to 4.000
0.000 to 1.000
-1
/
rad
Orientation on stop (5)
OFF (0) or On (1)
0 to 250
0 to 65,535
0 to 4,096
OFF (0) or On (1)
OFF (0) or On (1)
0.0 to 4,000.0 rpm
OFF (0) or On (1)
OFF (0) or On (1)
0 to 65,535
0 to 65,535
0 to 65,535
OFF (0) or On (1)
OFF (0) or On (1)
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
PLC
parameters
Data
Default( )
RO
RO Uni
RO Uni
drv (0)
RW Uni
drv (0)
RW Uni
OFF (0)
RW Bit
1.000
RW Uni
1.000
RW Uni
25.00
RW Uni
Position controller disabled (0) RW Uni
OFF (0)
RW Bit
150
RW Uni
0
RW Uni
256
RW Uni
RO Bit
OFF (0)
RW Bit
0.0
RW Uni
OFF (0)
RW Bit
OFF (0)
RW Bit
0
RW Uni
0
RW Uni
0
RW Uni
OFF (0)
RW Bit
OFF (0)
RW Bit
Txt
Text string
US
User save
Digitax ST User Guide
UL listing
Diagnostics
information
Type
Bi
NC PT
NC PT
NC PT
US
US
US
US
US
US
US
US
US
US
US
NC PT
NC
NC
NC
NC
NC
NC
NC
NC
US
PS
Power down save
Issue Number: 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents