Menu 11: General Drive Set-Up - Emerson Digitax ST User Manual

Hide thumbs Also See for Digitax ST:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
installation
11.11

Menu 11: General drive set-up

Parameter
11.01 Parameter 0.11 set up
11.02 Parameter 0.12 set up
11.03 Parameter 0.13 set up
11.04 Parameter 0.14 set up
11.05 Parameter 0.15 set up
11.06 Parameter 0.16 set up
11.07 Parameter 0.17 set up
11.08 Parameter 0.18 set up
11.09 Parameter 0.19 set up
11.10 Parameter 0.20 set up
11.11 Parameter 0.21 set up
11.12 Parameter 0.22 set up
11.13 Parameter 0.23 set up
11.14 Parameter 0.24 set up
11.15 Parameter 0.25 set up
11.16 Parameter 0.26 set up
11.17 Parameter 0.27 set up
11.18 Parameter 0.28 set up
11.19 Parameter 0.29 set up
11.20 Parameter 0.30 set up
11.21 Parameter scaling
11.22 Parameter displayed at power-up
11.23 Serial address
11.24 Serial mode
11.25 Baud rate
11.26 Minimum comms transmit delay
11.28 Drive derivative
11.29 Software version
11.30 User security code
11.32 Maximum current rating
11.33 Drive voltage rating
11.34 Software sub-version
11.35 Number of modules
SMARTCARD parameter
11.36
data previously loaded
11.37 SMARTCARD data number
11.38 SMARTCARD data type / mode
11.39 SMARTCARD data version
11.40 SMARTCARD data checksum
11.41 Status mode timeout
11.42 Parameter copying
11.43 Load defaults
11.44 Security status
11.45 Select motor 2 parameters
11.46 Defaults previously loaded
11.47 Drive Onboard PLC program enable
11.48 Drive Onboard PLC program status
Drive Onboard PLC programming
11.49
events
Drive Onboard PLC program average
11.50
scan time
11.51 Drive Onboard PLC program first run
Drive serial number least significant 9
11.52
digits
Drive serial number most significant
11.53
digits
* Modes 1 and 2 are not user saved, Modes 0, 3 and 4 are user saved
RW Read / Write
RO
Read only
FI
Filtered
DE
Destination
114
Electrical
Getting
Basic
installation
started
parameters
Range( )
Pr 1.00 to Pr 21.51
0.000 to 9.999
Pr 0.00 to 00.50
{0.37}
0 to 247
{0.35}
AnSI (0), rtU (1), Lcd (2)
300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4),
{0.36}
9600 (5), 19200 (6), 38400 (7),
57600 (8)*, 115200 (9)* *Modbus RTU only
0 to 250ms
0 to 16
{0.50}
1.00 to 99.99
{0.34}
0 to 999
{0.32}
0.00 to 9999.99A
{0.31}
200 (0), 400 (1), 575 (2), 690 (3)
0 to 99
0 to 10
{0.29}
0 to 999
0 to 1003
0 to 18
0 to 9,999
0 to 65,335
0 to 250s
nonE (0), rEAd (1), Prog (2), AutO (3),
{0.30}
boot (4)
nonE (0), Eur (1), USA (2)
{0.49}
L1 (0), L2 (1), Loc (2)
OFF (0) or On (1)
0 to 2000
Halt program (0)
Run program: out of range = clip (1)
Run program: out of range = trip (2)
-128 to +127
0 to 65,535
0 to 65,535 ms
OFF (0) or On (1)
0 to 999999999
0 to 65535
Uni
Unipolar
Bi
NC
Not copied
RA
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
Run program: out of range = trip (2)
Bi-polar
Bit
Bit parameter
Rating dependent
PT
Protected
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
Data
Default( )
Pr 3.29
RW Uni
Pr 4.01
RW Uni
Pr 7.07
RW Uni
Pr 4.11
RW Uni
Pr 2.04
RW Uni
Pr 2.02
RW Uni
Pr 4.12
RW Uni
Pr 8.29
RW Uni
Pr 7.11
RW Uni
Pr 7.14
RW Uni
Pr 7.15
RW Uni
Pr 1.10
RW Uni
Pr 1.05
RW Uni
Pr 1.21
RW Uni
Pr 1.22
RW Uni
Pr 3.08
RW Uni
Pr 3.34
RW Uni
Pr 6.13
RW Uni
Pr 11.36
RW Uni
Pr 11.42
RW Uni
1.000
RW Uni
Pr 0.10
RW Uni
1
RW Uni
rtU (1)
RW Txt
19200 (6)
RW Txt
2
RW Uni
RO Uni
RO Uni
0
RW Uni
RO Uni
RO Txt
RO Uni
0
RW Uni
0
RO Uni
0
RW Uni
RO Txt
0
RW Uni
RO Uni
240
RW Uni
nonE (0)
RW Txt
nonE (0)
RW Txt
RW Txt
OFF (0)
RW Bit
RO Uni
RW Uni
RO
RO Uni
RO Uni
RO Bit
RO Uni
RO Uni
Txt
Text string
US
User save
PS
Digitax ST User Guide
UL listing
information
Type
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
PT US
US
PT US
US
PT US
US
US
NC PT
NC PT
NC PT PS
NC PT
NC PT
NC PT
PT US
NC PT US
NC
NC PT
NC
NC PT
US
NC
*
NC
PT US
US
NC PT US
US
Bi
NC PT
NC PT PS
NC PT
NC PT
NC PT
NC PT
Power down save