External Emc Filter Rating; Figure 3-8 Din Rail Mounting; Figure 3-9 Bookcase Mounting; Figure 3-10 Footprint Mounting - Emerson Digitax ST User Manual

Hide thumbs Also See for Digitax ST:
Table of Contents

Advertisement

Safety
Product
Mechanical
Information
information
installation
Digitax ST can be mounted using a DIN rail, either fixed at the top or the
bottom of the drive (as illustrated in Figure ). Two screws are required to
fix the drive to the backplate at the opposite end to the DIN rail.

Figure 3-8 DIN rail mounting

47mm (1.85in)
312.7mm
(12.31in)
3.5

External EMC filter rating

Filter details for each drive rating are provided in the tables below.

Table 3-1 External EMC filter ratings

Number
Used with
of
phases
CT
DST120X
1
4200-6000
DST120X
3
4200-6001
DST140X
3
4200-6002
The external EMC filters can be footprint or bookcase mounted, see Figure 3-9 and Figure 3-10.

Figure 3-9 Bookcase mounting

18
Electrical
Getting
Basic
installation
started
parameters
Maximum
Filter part number
continuous
@40°C
Schaffner
(104°F)
A
FS23072-19-07
19
FS23073-17-07
17
FS23074-11-07
11
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
Power
losses
at rated
current
IP
current
rating
@50°C
(122°F)
W
A
17.3
11
15.5
13
20
10
10

Figure 3-10 Footprint mounting

Onboard
Advanced
Technical
PLC
parameters
Data
Worst
Operational
case
Weight
leakage
leakage
current
current
Kg
lb
mA
mA
1.2
2.64
29.5
56.9
1.2
2.64
8
1.2
2.64
16
Digitax ST User Guide
UL listing
Diagnostics
information
Filter
terminal
tightening
torque
Nm
lb ft
0.8
0.6
50
0.8
0.6
90
0.8
0.6
Issue: 3