Continuous Mode Speed Control
When continuous mode operation is started, pulse output will be continued
until it is stopped from the program.
Note Pulse output will stop immediately if the CPU Unit is changed to PROGRAM
mode.
Frequency changes
Pulse frequency
Target frequency
Execution of SPED(885)
Pulse frequency
Target frequency
Present frequency
Pulse frequency
Present frequency
Execution of INI(880)
Pulse frequency
Present frequency
Execution of SPED(885)
■
Independent Mode Positioning
When independent mode operation is started, pulse output will be continued
until the specified number of pulses has been output.
1. Pulse output will stop immediately if the CPU Unit is changed to PRO-
GRAM mode.
2. The number of output pulses must be set each time output is restarted.
3. The number of output pulses must be set in advance with PULS(881).
Pulses will not be output for SPED(885) if PULS(881) is not executed first.
4. The direction set in the SPED(885) operand will be ignored if the number
of pulses is set with PULS(881) as an absolute value.
Time
Time
Execution of
SPED(885)
Time
Time
Section 5-5
Description
Procedure/
instruction
Outputs pulses at a
SPED(885) (Con-
specified frequency.
tinuous)
Changes the fre-
SPED(885) (Con-
quency (higher or
tinuous)
lower) of the pulse
↓
output in one step.
SPED(885) (Con-
tinuous)
Stops the pulse out-
SPED(885) (Con-
put immediately.
tinuous)
↓
INI(880)
Stops the pulse out-
SPED(885) (Con-
put immediately.
tinuous)
↓
SPED(885) (Con-
tinuous, Target fre-
quency of 0 Hz)