Operating Mode 2 Connection Example - Omron CJ1M-CPU21 Operation Manual

Cj-series built-in i/o cpu units
Hide thumbs Also See for CJ1M-CPU21:
Table of Contents

Advertisement

Wiring Examples
Origin Search Operation
Example PLC Setup
Settings

Operating Mode 2 Connection Example

The origin search operation is completed at the first phase-Z signal after the
rising edge of the Origin Proximity Input Signal is detected, deceleration is
completed, and the falling edge of the Origin Proximity Input Signal is
detected.
ORG(889)
instruction
Origin Proximity
Input Signal
Origin Input Signal
(phase-Z signal)
Pulse signal
Error Counter
Reset Output
Programming
Bits
Console
address
256
00 to 03
257
00 to 03
04 to 07
08 to 11
12 to 15
268
00 to 03
04 to 07
08 to 11
12 to 15
Operating mode 2 is the same as operating mode 1 except that the servo
driver's Positioning Completed Signal (INP) is used as the origin search's
Positioning Completed Signal.
In this example, a servo driver is used and the encoder's phase-Z output is
used as the Origin Input Signal terminal. The servo driver is an OMRON
Servo Driver (W-series, U-series, or SMART STEP A-series.
Set the Servo Driver so that the Positioning Completed Signal is OFF when
the motor is operating and ON when the motor is stopped. The origin search
operation won't end if the Positioning Completed Signal is not connected cor-
rectly from the Servo Driver or is not set correctly.
Approx. 20 to 30 ms
Setting
1 hex
Enable origin search function for pulse
output 0.
1 hex
Operating mode 1
0 hex
Reverse mode 1
0 hex
Read Origin Input Signal after Origin
Proximity Input Signal goes from OFF
to ON to OFF again.
0 hex
Search direction is CW.
0 hex
Limit Input Signal is a NC contact.
1 hex
Origin Proximity Input Signal is a NO
contact.
1 hex
Origin Input Signal is a NO contact.
0 hex
---
Section 3-3
Time
Function
45