Auxiliary Area Data Allocation
4-3-2

Auxiliary Area Flags and Bits for Built-in Outputs

Name
Address
Pulse Output 0 PV
A276 to
A277
Pulse Output 1 PV
A278 to
A279
Pulse Output 0
A28000
Accel/Decel Flag
Pulse Output 0
A28001
Overflow/Underflow
Flag
Pulse Output 0 Out-
A28002
put Amount Set Flag
72
The following tables show the Auxiliary Area words and bits that are related to
the CJ1M CPU Unit's built-in outputs. These allocations apply to CPU Units
equipped with the built-in I/O functions only.
Description
Contain the number of pulses output from the
corresponding pulse output port.
PV range: 80000000 to 7FFFFFFF hex
(−2,147,483,648 to 2,147,483,647)
When pulses are being output in the CW direc-
tion, the PV is incremented by 1 for each pulse.
When pulses are being output in the CCW direc-
tion, the PV is decremented by 1 for each pulse.
PV after overflow: 7FFFFFFF hex
PV after underflow: 80000000 hex
A277 contains the leftmost 4 digits and A276
contains the rightmost 4 digits of the pulse out-
put 0 PV.
A279 contains the leftmost 4 digits and A278
contains the rightmost 4 digits of the pulse out-
put 1 PV.
Note If the coordinate system is relative coor-
dinates (undefined origin), the PV will be
cleared to 0 when a pulse output starts,
i.e. when a pulse output instruction
(SPED(885), ACC(888), or PLS2(887)) is
executed.
This flag will be ON when pulses are being out-
put from pulse output 0 according to an
ACC(888) or PLS2(887) instruction and the out-
put frequency is being changed in steps (accel-
erating or decelerating).
0: Constant speed
1: Accelerating or decelerating
This flag indicates when an overflow or under-
flow has occurred in the pulse output 0 PV.
0: Normal
1: Overflow or underflow
ON when the number of output pulses for pulse
output 0 has been set with the PULS instruction.
0: No setting
1: Setting made
Section 4-3
Read/Write Times when data is
accessed
Read only
• Cleared when
power is turned
ON.
• Cleared when
operation starts.
• Refreshed each
cycle during over-
see process.
• Refreshed when
the INI(880)
instruction is exe-
cuted for the cor-
responding pulse
output.
Read only
• Cleared when
power is turned
ON.
• Cleared when
operation starts or
stops.
• Refreshed each
cycle during over-
see process.
Read only
• Cleared when
power is turned
ON.
• Cleared when
operation starts.
• Cleared when the
PV is changed by
the INI(880)
instruction.
• Refreshed when
an overflow or
underflow occurs.
Read only
• Cleared when
power is turned
ON.
• Cleared when
operation starts or
stops.
• Refreshed when
the PULS instruc-
tion is executed.
• Refreshed when
pulse output
stops.