(Odu,Enable,Config) Miscellaneous; (Odu,Enable,Config,Miscellaneous) Agc (Auto Gain Control); (Odu,Enable,Config,Miscellaneous) Ref-Adjust; (Odu,Enable) Info (Information) - Comtech EF Data CDM-550T Manual

Hide thumbs Also See for CDM-550T:
Table of Contents

Advertisement

CDM-550T Satellite Modem
KST-2000A FSK Remote Operation
1.2.19
(ODU,ENABLE, CONFIG)
This menu item is used to select miscellaneous ODU parameters for
modification. Use the [←] [→] keys, then press <ENTER>.
1.2.20
(ODU,ENABLE,CONFIG,MISCELLANEOUS)
The user is prompted to select either OFF, ON or BURST, using the [←] [→]
keys, then to press <ENTER>.
1.2.21
(ODU,ENABLE,CONFIG,MISCELLANEOUS)
The user is prompted to edit the INT 10MHz REF setting using the [↑] [↓] keys,
then to press <ENTER>. The value will scroll between 000 and 255.
Note: The INT REF is adjusted in the factory to be very accurate with the default
setting of 028. This parameter is made available to compensate for the long-
term frequency drift of the oscillator.
1.2.22
(ODU,ENABLE)
INFO: TX RX
The operator uses this menu item to select enter 1 of 7 'Information Windows'.
Use the [←] [→] keys, then press <ENTER>.
KST MISC: AGC
REF-ADJUST
(ENTER)
SEL AGC MODE:
OFF ON BURST (ENTER)
EDIT INT REF ADJUSTMENT:
028 (PRESS ENTER)
INFO (Information)
HPA LNA EQUIP
ASSEMBLY+SN FW (ENTER)
8
MISCELLANEOUS
AGC (Auto Gain Control)
REF-ADJUST
Revision 0