Front Panel Operation
6–8
(CONFIG, TX, FEC)
Select Viterbi, Sequential, Viterbi + concatenated Reed-Solomon, Sequential +
concatenated Reed-Solomon, or None, using the LEFT/RIGHT arrow keys, then
press ENTER.
If the Turbo Codec option is installed, the following menu will be displayed:
SELECT FEC TYPE: VITERBI
SEQ
TURBO
NONE (ENTER)
(CONFIG, TX, FEC)
Select Viterbi, Sequential, Turbo or None, using the LEFT/RIGHT arrow keys,
then press ENTER.
(CONFIG, TX, FEC, RATE
Except Turbo)
SELECT FEC ENCODER RATE:
1/2
3/4
7/8(PRESS ENT)
Select Rate 1/2, Rate 3/4 or Rate 7/8 encoding rate, using the LEFT/RIGHT
arrow keys, then press ENTER.
Note: If BPSK is selected, only Rate 1/2 is permitted. A warning screen appears
if this sub-branch is entered when in BPSK mode.
If Turbo is selected, the following sub-menu will be displayed:
CDM-550T Satellite Modem
FEC Rate (Any FEC Type
)
Rev. 1.3