Comtech EF Data CDM-550T Manual page 52

Hide thumbs Also See for CDM-550T:
Table of Contents

Advertisement

Front Panel Operation
6.2.3.3
(CONFIG) INTFC (Interface)
6.2.3.4
(CONFIG) REMCONT (Remote control)
6–22
(CONFIG, FRAME, FRAMED, ON)
EDIT THIS UNIT'S ADDRESS
0245 (SEE HANDBOOK)(ENT)
Edit the address of this SLAVE unit. This is accomplished by selecting the digit
to be edited, using the LEFT/RIGHT arrow keys. The value of the digit is then
changed using the UP/DOWN arrow keys. The user should then press ENTER.
The valid range of addresses is from 1 to 9999, although 'base 10' values will be
automatically skipped.
Remember that this is a unit which is intended to be located at the distant-end of
a link, and will therefore be under the control of a MASTER at the other end.
This is the equivalent of putting the unit into Remote Control mode - no local
control is possible.
DATA INTERFACE:
V.35
RS232
Select RS422 (EIA 530), V.35, or RS232, using the LEFT/RIGHT arrow keys,
then press ENTER. Please refer to Section 10 for details on using the RS232
interface in asynchronous mode.
SELECT REMOTE CONTROL:
LOCAL REMOTE (PRESS ENT)
Select LOCAL or REMOTE using the LEFT/RIGHT arrow keys, then press
ENTER.
EDMAC SLAVE
RS422
(ENTER)
CDM-550T Satellite Modem