Electronic Control Troubleshooting
To reduce the risk of electric shock, fire, explosion,
serious injury or death:
•
Disconnect electric power to the dryer before
servicing.
•
Close gas shut-of valve to gas dryer before serv-
icing.
•
Never start the Dryer with any guards/panels re-
moved.
•
Whenever ground wires are removed during serv-
icing, these ground wires must be reconnected to
ensure that the dryer is properly grounded.
Display
EI01
EI02
EI03
EI04
EI05
EI09
EI0A
EI0C
EI0E
EI0F
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
WARNING
Transmission Failure
Device Time-out
Invalid Command Code
Command Packet Time Out
Invalid or Out-of-Range Data
CRC-16 Error
Framing Error
Time-out Exceeded
Encryption Error
Invalid Wake-up or Infra-red Disabled
Error Codes
Following is a list of possible error codes for an electronic con-
trol. Errors beginning with EI refer to external device Infra-red
communication errors. Errors beginning with EC refer to card
reader errors. All other errors refer to machine errors.
W001R1
Description
Table 1 continues...
34
Electronic Control Troubleshooting
Cause/ Corrective Action
Communication failure. Re-aim external
device and try again.
Communication failure. Re-aim external
device and try again.
Incorrect machine type. Before download-
ing, ensure data is for current machine
type.
Communication failure. Re-aim external
device and try again.
Incorrect machine type. Before download-
ing, ensure data is for current machine
type and values entered are within the min-
imum and maximum limits.
Communication failure. Re-aim external
device and try again.
Communication error. Re-aim external de-
vice and try again.
Communication error. Re-aim external de-
vice and try again.
Incorrect machine type. Before download-
ing, ensure data is for current machine
type.
Communication failure or infra-red is disa-
bled. Manually enable infra-red on control
or re-aim external device and try again.
Part No. D515519R3