HBM MP85A Operating Manual page 55

Twin-channel-amplifiers
Hide thumbs Also See for MP85A:
Table of Contents

Advertisement

MP85A process controller
Fig. 6.6: Online window
Process window
This window type checks the course of a curve in the window area.
The curve must run through the window as defined from the entry side to the
exit side, without violating any of the other window limits. The entry and the
exit sides are user-selectable (left, right, top, bottom, any).
Fig. 6.7: Process window
Block window
The block window monitors the block size and the block force of a press-fit
process. With this window type, the curve must enter at the given entry side
and must not exit the window. The entry side is user-selectable (left, right, top,
bottom, any).
Fig. 6.8: Block window
A2392−5.0 en
Error during thread-in ! Force too great !
Real-time signal "Withdraw press"
Approved
block force
Approved block
size
55
HBM