MP85A process controller
Fig. 6.2: Time-driven process curve determination

6.2 Classification

Classifying X or Y
Measured quantities on channel X, such as length, thickness and diameter or
channel Y, such as force, weight, torque, etc., can be divided into 5 groups
per window. This means that e.g. springs can be automatically sorted by
spring rate.
Fig. 6.3: Classifying the measurands of a tolerance window
NOTE
Statistics and classification can only be used when using the 31 Flash para-
meter sets, not with memory card or PC parameter sets.

6.3 Monitoring limit values in real time

A total of eight limit values can be assigned and monitored in real time for
channels X and Y. A switching signal of choice can be allocated to each limit
value. This allows a press, for example, to be switched over from "fast" to
"slow". The circuit logic can also be inverted.
A2392−5.0 en
y
max
y
min
53