6.6 Measurement programs (parameter sets)

A total of 31 measurement programs can be activated from the MP85A
process controller's internal (flash) memory for 31 different workpieces. A
measurement program comprises a workpiece-specific parameter set
consisting of the settings of the amplifier for the sensor technology, measure-
ment acquisition and storage, function assignments of the digital inputs/
outputs and the evaluation methods.
The parameter sets are loaded from the MP85A process controller flash
memory to the RAM via digital input/outputs, bus commands or the PME
Assistant programs (Chapter 8.6).
CAUTION
Parameter sets may only be switched after the end of a process, not
during a measurement. The next process may only be started once para-
meter set switching is complete (see Chapter 8.1, Machine control).
Fig. 6.13: Measurement program processing
In addition, e.g. as data backup, parameter sets can also be transferred to the
MMC/PC card of the MP85A process controller or connected computer. The
PME Assistant or INDUSTRYmonitor software is required for transfer to PC.
HBM
Internal buffer
(RAM):
Current
parameter set
Internal flash
(EEPROM):
31 parameter sets
+ factory settings
MMC/PC Card
1000 parameter sets
MP85A process controller
A2392−5.0 en