Omron e5ck User Manual page 170

Digital controller (programmable type)
Hide thumbs Also See for e5ck:
Table of Contents

Advertisement

JCharacteristics
Indication Accuracy
Temperature variation influ-
ence (*2)
Voltage variation influence
(*2)
Hysteresis
Proportional Band (P)
Integral Time (I)
Derivative Time (D)
Control Period
Manual Reset Value
Alarm Setting Range
Sampling Period
Program Method
Program Size
Program Time Accuracy
Insulation Resistance
Dielectric Strength
Malfunction 10 to 55 Hz, 10m/s
Vibration
Vibration
Resistance
Destruction 10 to 55 Hz, 10m/s
Malfunction
Shock
Resistance
Resistance
Destruction 300 m/s
Weight
Enclosure Ratings
Memory Protection
*1 The indication accuracy of the K1, T and N thermocouples at a temperature of 100C or less is ±2°C ±1 digit maximum. The
indication accuracy of the U, L1 and L2 thermocouples at any temperature is ±2C ±1 digit maximum.
The indication accuracy of the B thermocouple at a temperature of 400°C or less is unrestricted.
The indication accuracy of the R and S thermocouples at a temperature of 200°C or less is ±3°C ±1 digit maximum.
The indication accuracy of the W thermocouple ±1 digit max. of whichever is the greater of ±0.3% or ±3°C of the indicated
value.
The indication accuracy of the PLII thermocouple is ±1 digit max. of whichever is the greater of ±0.3% or ±2°C of the indi
cated value.
*2 Ambient temperature: -10°C to 23°C to 55°C
Voltage range: -15 to +10% of rated voltage
*3 Write operations: Parameter changes, remote/local selection, etc.
Thermometer:
(±0.3% of indication value or ±1°C, whichever greater) ±1 digit max. (*1)
Platinum resistance thermometer:
(±0.2% of indication value or ± 0.8°C whichever greater) ±1 digit max.
Analog input: ±0.2%FS±1 digit max.
Platinum resistance thermometer:
(±1% of PV or ± 2°C, whichever greater) ±1 digit max.
Thermocouple (R, S, B, W):
(±1% of PV or ± 10°C, whichever greater) ±1 digit max.
(±1% of PV or ± 10°C whichever greater) ±1 digit max
Other thermocouples (K1, K2, J1, J2, E, N, T, L1, L2, U, PLII):
(±1% of PV or ± 4°C, whichever greater) ±1 digit max.
Analog input (current, voltage, or remote SP input): ±1%FS±1 digit max.
0.01 to 99.99%FS (in units of 0.1%FS)
0.1 to 999.9%FS (in units of 0.1%FS)
0 to 3999s (in units of 1 second)
0 to 3999s (in units of 1 second)
1 to 99s (in units of 1 second)
0.0 to 100.0% (in units of 0.1%)
-1999 to 9999 (decimal point position dependent on input type)
Temperature input: 250 ms, Analog input: 100 ms.
Set time or rate of rise programming
Max. 4 patterns, Max. 16 steps/pattern
±0.2% ±500 ms of set value (even-numbered steps in the "rate of rise program-
ming" setting are set to the time unit of ramp rate)
20 MW min. (at 500 VDC)
2000 VAC, 50/60 Hz for 1 min. (between electrically live terminals of different
polarities)
2
{approx. 1G} for 10 min. each in X, Y, and Z directions
2
{approx. 2G} for 2 hrs. each in X, Y, and Z directions
2
200 m/s
min. {approx. 20G}, 3 times each in 6 directions (100 m/s
10G} applied to the relay)
2
min. {approx. 30G}, 3 times each in 6 directions
Approx. 170 g, adapter: approx. 10 g
Front panel: NEMA4 for indoor use (equivalent to IP66)
Fear case: IP20
Terminals: IP00
Non-volatile memory (number of writes: 100,000) (*3)
SPECIFICATIONS
2
{approx.
A–3