Setup GUI – EVENTS – Overview
The D*AP4 VAP offers a sophisticated event management system.
The event system performs Actions. These Actions are built from Events.
Actions may be triggered manually (via the X*AP RM
semi-automatically (triggered by network commands or GPIs) and automatically (triggered by changes of
parameters and/or the internal status) or as a combination of all three.
The overview shows the building blocks of the action management of the D*AP4 VAP.
The examples further below are taken from the actual set of factory pre-set events based on a number
of useful presets:
A trigger is subdivided into a trigger type and a trigger source. E.g. a GPI is a trigger type while its
number (the physical input) represents the trigger source. Other trigger types have sources which must
be configured, like the names of X*AP Hotkeys or network triggers.
Hotkey Sources
Network Sources
Parameter Sources
The triggers will finally be defined by a trigger equation that may be the logical combination of two
trigger sources.
The D*AP4 VAP knows five different event types:
Preset Events (Profiles)
Parameter Events
Measurement Events
I/O Events
Bypass Events
remote panel Hotkeys or from the operator UI),
1
You may assign hotkeys of the X*AP remote and / or the
mobile UI to become a trigger source.
Received via the EmBER+ protocol.
Device parameters / status information grouped into
systems and Interfaces.
System / Interfaces / Routing / Audio Processor /
Voice / Program / Monitor
System / Audio Processor / Measurement
Pause / Continue / Reset / Reset Max / Start / Pause / Stop
GPOs
Voice / Program
67