D*AP4 VAP
This Device
Serial Number
Name
Location
Admin / Contact
Graphical User Interface
Startup Page View
Device Time
Date
Time
Authentication
Enable
Change Password for
Password
Repeat
Important Note! The authentication may be enabled / disabled form the console interface as well
(see page 8 "1: Manage Password") via USB connection but also via Telnet! If you have higher security
demands you should turn the Telnet server off. Authentication will be turned off and passwords will be reset if
one initializes the device to factory default (see Reboot - page 19, INIT/RESET rear button - page 4).
If there was an authentication failure, the admin will be notified at
the next proper login about such conditions. The pop up appears
for each login that has failed. It shows the IP address of the device
that caused the Authentication failure.
After a correct login the status "who" (e.g. admin)
and a <Log Out> button are available from the GUI:
Network
IP Address
Netmask
Gateway
Input fields for information utilized by higher level services.
The electronic serial number. It is printed on a label at the rear of the
device.
Give the device a meaningful name that may be used by name services
and SNMP management.
The place where the D*AP4 VAP is located.
e-mail address of a person in charge.
Defines the appearance of the parameter panes regarding preset editor
and on air parameter visibility (see below – for preset concept).
Defines the appearance of the parameter panes regarding preset editor
and on-air parameter visibility (see below – for preset concept).
Allows you to set the device clock. At the factory it is set to
UTC (Coordinated Universal Time).
If you click into the Date input field, you'll get a calendar tool:
If you click into the Time input field,
you will be able to set the device time:
To prevent non-authorized people from
changing D*AP4 VAP settings the
administrator may assign passwords for
either the admin and/or an operator
(same applies for talent/artist). While the admin is allowed to set everything,
an operator is just allowed to load presets. Parameters will be reset if the
operator attempted to change it.
[enable / disable]
The administrator may turn authentication off.
[ON / OFF]
Select which password you will set / change.
Type in a password
Default passwords are: admin (for admin) and operator (for operator).
repeat that password
IP address setup, see above:
getting started – IP setup of the D*AP4 VAP
The address of your choice – default [10.110.xxx.yyy]
The net mask of your network – default [255.255.0.0]
The optional gateway address – default [0.0.0.0]