Setup GUI – EVENTS – Triggers – Configuration – Trigger Equation
To form a trigger you may logically combine two trigger sources:
Trigger
Source 1
Invert
Type
Source
Logic
Source 2
Here you define a name for the trigger (Trigger 1).
The first source of a logical combination of two trigger sources.
[ON / OFF]
If the type of trigger allows an inverted operation it can be defined here.
[GPI / Hot Key, Network / Parameter / Event active / Trigger effective/
Bypass / Sync Lock]
[e.g. for GPIs it will be 1 ... 8]
It acts like an index for the trigger type (In case of GPI it is the physical
GPI number or in case of X*AP Hotkeys the key number (1 of 8)
Kind of logical operation [and, or, xor].
Second source for the logical combination of two trigger sources. If only
one source exists, you may leave it unassigned [-].