Operating - Menu Structure Of The X*Ap Remote Panel - Power Up Display - junger D*AP4 VAP Edition Manual

Voice audio processors
Table of Contents

Advertisement

Afterwards you must reboot the D*AP4 unit in order to activate the new IP configuration.
Important Note! After reboot neither the web browser nor the X*AP RM
communicate with the D*AP4 device. You must fill in the new IP address in the URL field and change
the X*AP RM
remote panel settings to attach this device with its new IP address.
1
Operating - menu structure of the X*AP RM
Power up display – may show up to four D*APx which are enabled for remote control via this X*AP RM
remote panel. The example below has just one D*AP4 VAP unit [given name "Voiceproc 3"] attached for
remote control. The status is "connect" (i.e. you may connect with that device).
See X*AP RM1 manual for details.
Remote Panel select device to control
Voiceproc 3
10.110.1.55 [Voice1]
connect
Pressing that button will connect with the D*AP4 VAP.
Now the X*AP RM
(this may take a few seconds). When finished the main operating display opens up.
The appearance of that display depends on the setting found in:
SYSTEM > Remote Access > X*AP Remote > X*AP Remote Feature Set. If it is set to
"Load Profiles [Voice x]" the capabilities are limited to load such profiles, to control the cough cut and to
activate the voice over function manually (AUDIO PROCESSOR > Voice Over > Mode = "Manual"):
Voice 1
Cough Cut
Voice Over
Mic Active
OFF
From here you may fire pre-defined hotkeys and observe the status of both voice channels.
"Voice 1" is the default name of the first voice channel.
If SYSTEM > Setup > Voice Channel Mode = Stereo, settings will be made in reference to the first voice
channel. Because this is the main operating display, the <ESC> button lights
power up display is below the main operating display.
Pressing
<ESC>
If the X*AP Remote Feature Set "Standard Set" is selected, this main operating display will be shown
(example for Voice Channel Mode = Stereo):
Voice 1
-
Clear
Just De-Ess
Now you may fire the pre-set actions (see EVENTS > Actions > Event Actions) via the hotkeys.
You may configure these buttons via: EVENTS > Triggers > Remote Hotkeys and > Trigger Equations.
remote panel – power up display
1
remote panel will gather all necessary information from that D*AP4 VAP unit
1
Voiceproc 3
ON AIR
Load Profile
_
sends you back to the power up display (device selection).
Voiceproc 3
ON AIR
Mic Active
Gentle
Radio
remote panel may be able to
1
10.110.88.135
10.110.88.135 .
Normalize
Heavy
10
D*AP4 VAP
MENU
ESC
MENU
ESC
red
to indicate that the
MENU
Panic
ESC
1

Advertisement

Table of Contents
loading

Table of Contents