Recommended fuel

Use a fuel specified in this manual only. Do not refill
the fuel tank more than the specified level, as it may
result in a fire.
Use a diesel fuel equivalent for "JIS K 2204 diasel

fuel".

It is necessary to use a fuel that has a pour point suit-
able for the ambient temperature.

Handling fuel

When using fuel stored in a storage tank, leave it to sit for more than 24 hours so that dust and water can settle at
the bottom. Then, use the upper clean fuel.
Fill up the fuel tank or service tank after each operation.
This prevents water from mixing with fuel in the tank and also gives time for dust and water to separate and settle at
the bottom of the tank.
Before refilling, clean the areas around the caps thoroughly and remove the caps from the drum and tank. Also
clean your hands and the hose before refueling. When using a hand-operated pump, be careful not to pump water
or sediment accumulated at the bottom of the storage tank.
Be sure to use a strainer when filling fuel tank. For a complete filtration, it is recommended to use a clean lint-free
cloth together with the strainer.
Chapter 4 FUEL
Fig. 4-1 Recommended fuel
140/242
Diesel fuel
equivalent
for
JIS K2204
4-1