6.3.2 Starting
Check that the generating set circuit breaker has triggered.
Danger
Connect the generating set battery
Turn the key switch to the ON position (without forcing it to the ON position), the ON lamp will light up (if the lamp does not
light up, check and replace the fuse if necessary)
Test the Alarm and Fault LEDs (menu 15 – TEST LAMPS)
1 ACTIONS
1/5
11 MANUAL <> AUTO
12 CONTROL LOAD
13 TEST GENERATING SET
14 PROGRAMS
15 TEST LAMPS
OK
Esc
Press "Esc" several times to return to the following home menu
OPERATION
MANUAL
Press START
to start
24/08/2005
Check the battery voltage
Press START:
AIR PREHEATING
10 seconds
24/08/2005
If the engine is equipped with an
air preheating system, there is a
delay (adjustable)
before
engine
starts
(preheating
activation period).
If the motor is not fitted with an
air preheating system or once the
preheating delay has elapsed,
the engine starts up (start of a
cycle comprising 3 attempts to
start up the engine).
13:12
START-UP
IN PROGRESS
24/08/2005
13:12
Warning: the number of successive
and automatic starting attempts is
limited to 3.
the
The following pictogram will flash
AVAILABLE POWER
13:12
24/08/2005
The following pictogram is displayed
The following information is displayed
76/242
100.0%
13:12
Speed of rotation
Coolant temperature
Oil pressure
Oil Temperature