Reporting Commands; The Resetconfiguration Command; Parameter Setting Commands - Rice Lake IQ PLUS 710 Installation Manual

Digital weight indicator
Hide thumbs Also See for IQ PLUS 710:
Table of Contents

Advertisement

5.1.2

Reporting Commands

Reporting commands (see Table 5-2) send speciÞc
information to the EDP port. These commands can be
used in both setup mode and normal mode.
Command
DUMPALL
List all parameter values
SPDUMP
Print setpoint configuration
VERSION
Write IQ plus 710 software version
P
Write current displayed weight with units
identifier. See Section 10.2 on page 68 for
more information.
S
Write one frame of stream format
Table 5-2. EDP Reporting Commands
5.1.4

Parameter Setting Commands

Parameter setting commands allow you to display or
change the current value for a particular conÞguration
parameter (Tables 5-3 through 5-12).
Current conÞguration parameter settings can be
displayed in either setup mode or normal mode using
the following syntax:
command<ENTER>
Most parameter values can be changed in setup mode
only; setpoint parameters listed in Table 5-8 on
page 44 can be changed when in normal weighing
mode.
Use the following command syntax when changing
parameter values:
command=value<ENTER>
Command
GRADS
Graduations
ZTRKBND
Zero track band
ZRANGE
Zero range
MOTBAND
Motion band
OVRLOAD
Overload
DIGFLTR1
Digital filtering
DIGFLTR2
RATLTRAP
Rattletrap filtering
DFSENS
Digital filter cutout sensitivity
DFTHRH
Digital filter cutout threshold
ALGFLTR
Analog filter
PWRUPMD
Power up mode
TAREFN
Tare function
Function
Description
1–100000
OFF, 0.5D, 1D, 3D
1.9%, 100%
1D, 2D, 3D, 5D, 10D, 20D, OFF
FS+2%, FS+1D, FS+9D, FS
1, 2, 4, 8, 16, 32, 64, 128, 256
OFF, ON
2OUT, 4OUT, 8OT, 16OUT, 32OUT, 64OUT, 128OUT
NONE, 2DD, 5DD, 10DD, 20DD, 50DD, 100DD, 200DD, 250DD
OFF, 2HZ, 8HZ
GO, DELAY
BOTH, NOTARE, PBTARE, KEYED
Table 5-3. CONFIG EDP Commands
5.1.3

The RESETCONFIGURATION Command

The RESETCONFIGURATION command can be
used in setup mode to restore all conÞguration
parameters to their default values.
This command is equivalent to using the DEFAULT
function in TEST mode. See Section 10.9 on page 76
for more information about test mode.
All load cell calibration settings are lost when
NOTE:
the RESETCONFIGURATION command is run.
where
is either a number or a parameter value.
value
Use no spaces before or after the equal (=) sign. If you
type an incorrect command, the display reads
For example, to set the motion band parameter to 5,
type the following:
MOTBAND=5D<ENTER>
For parameters with selectable values, enter the
command and equal sign followed by a question
mark:
command=?<ENTER>
to see a list of those values. The indicator must be in
setup mode to use this function.
Values
.
??
EDP Commands
41