10.10 Software Revision History - Rice Lake IQ PLUS 710 Installation Manual

Digital weight indicator
Hide thumbs Also See for IQ PLUS 710:
Table of Contents

Advertisement

TEST Menu
Function
CLEAR EEPROM Clear EEPROM
Read Caution! statement on page 76 before using this function.
Press and hold the setup switch, then press the
A/D OFFSET
A/D offset calibration (–0.5 mv/V)
Read Caution! statement on page 76 before using this function. Press and hold the setup switch,
then press the 8 key to perform offset calibration.
A/D GAIN
A/D gain calibration (+4.5 mv/V)
Read Caution! statement on page 76 before using this function. Press and hold the setup switch,
then press the 9 key to perform gain calibration.
EXIT
Press the 3 key to exit test mode.

10.10 Software Revision History

The following list summarizes the principal software
changes made for Version 2.0:
Analog and Digital Filtering
¥ ConÞgurable analog Þlter added with available
settings of OFF, 2HZ, 8HZ.
¥ Digital Þltering changed from one to two Þlters
(DIGFLT1 and DIGFLT2). New RATTRAP
parameter enables RATTLETRAP
for both digital Þlters.
Serial Communications and Printing
¥ PORT parameters removed from the SERIAL
menu.
¥ EDP port AB-RIO parameter name changed to
BUS; BUS parameter added to printer port.
¥ Printer port now supports duplex RS-232
communications; can be used to send and
receive EDP commands.
¥ Streamed weight information now uses the
following units designators: lb=L; Kg=K; oz=O;
gram=G; ton, metric ton, and long ton=T; grain,
troy ounce, troy pound, and none=space.
¥ Print command latches for three seconds: A
print command issued while the scale is in
motion is now completed if the scale comes out
of motion before the three seconds elapses.
¥ CONSNUM (consecutive numbering) and UID
(unit ID) parameters added to PROGRM menu.
Zero and Tare Operations
¥ Except in OIML mode, a tare is cleared by
pressing the
TARE
NTEP, CANADA, and OIML modes all require
the scale to be at no load before clearing a tare.
¥ Scale can now be zeroed (gross zero) with a tare
remaining in the system. Exception: In OIML
Table 10-7. Test Menu Functions (Continued)
¨
algorithm
(rather than
) key.
ZERO
Description
.
(decimal_point) key to clear EEPROM.
mode, the tare is cleared when the
pressed.
¥ Tare values restricted to six digits to avoid
display overßow when tare weight is removed.
See the listings under ÒTruck ModeÓ for more
tare-related changes.
Truck Mode
¥ In truck mode, you can now clear individual tare
values or the entire tare register.
¥ The word
TARE
TARE100 truck mode storage register printouts
to prevent labeling of stored weights as tare
weights.
¥ Truck mode tare storage register increased to
300 IDs.
¥ The truck mode storage register can now be
called up by pressing the
Setpoints
¥ The IQ plus 710 now supports up to 20
setpoints, including all setpoint kinds available
for the IQ plus 800/810 indicators.
¥ SETPNTS menu name changed to SETPTS.
¥ SPNAMES parameter has been removed from
SETPTS menu. A name can now be selected (for
any setpoint kind) from a list of up to 60
prompts deÞned on the PROGRM menu,
PROMPTS parameter.
¥ All setpoint kinds now default to ACCESS=ON.
Batching Operations
¥ Setpoint name can be displayed while a batch is
running.
¥ PREACT and BANDVAL values can be entered
at the front panel.
key is
ZERO
has been removed from
ID
key.
Appendix
77

Hide quick links:

Advertisement

Table of Contents
loading