About This Manual; Introduction; Operating Modes - Rice Lake IQ PLUS 710 Installation Manual

Digital weight indicator
Hide thumbs Also See for IQ PLUS 710:
Table of Contents

Advertisement

About This Manual

This manual is intended for use by service technicians
responsible for installing and servicing IQ plus
digital weight indicators.
This manual applies to indicators using Version 2.0 of
the IQ plus 710 software. See Section 10.10 on
page 77 for a summary of software changes included
in this release.
ConÞguration and calibration of the indicator can be
accomplished using the indicator front panel keys, the
EDP command set, or Version 2.4 or later of the
Revolution
ª
conÞguration utility. See Section 3.1 on
page 13 for information about conÞguration methods.
1.0

Introduction

The IQ plus 710 is a single-channel digital weight
indicator housed in a NEMA 4X/IP66-rated stainless
steel enclosure. The indicator front panel consists of a
2 9 - bu t t o n key p a d w i t h a l a rg e , s eve n - d i g i t ,
1 4 - s e g m e n t , va c u u m ß u o r e s c e n t d i s p l a y,
two-character dot-matrix annunciator Þeld, and a
sixteen-character dot-matrix prompt Þeld. Features
include:
Drives up to eight 350 W or sixteen 700 W load
¥
cells
¥
Supports 4- and 6-wire load cell connections
¥
Eight conÞgurable digital inputs
¥
Eight digital outputs
¥
Electronic data processing (EDP) port for full
duplex RS-232 or RS-485 communications at
up to 19200 bps
¥
Printer port for full duplex RS-232 and
o u t p u t - o n l y 2 0 m A c u r r e n t l o o p
communications at up to 19200 bps
¥
Optional analog output module provides 0Ð10
VDC or 4Ð20 mA tracking of gross or net
weight values
¥
Optional
Remote
communication with PLC
controllers using the Allen-Bradley
1
I/O networks
¥
Optional interface for ProÞbus
2
communications
¥
Available in 115 VAC and 230 VAC versions
®
®
1.
Allen-Bradley
, PLC
, and SLC
Company, Inc., a Rockwell International company.
®
2.
Profibus
is a registered trademark of Profibus International.
¨
710
I/O
Interface
for
¨
and SLC
ª
¨
Remote
¨
DP network
are trademarks of Allen-Bradley
Some procedures described in this
Warning
manual require work inside the indicator
enclosure. These procedures are to be
performed by qualified service personnel
only.
Authorized distributors and their employees
can view or download this manual from the
Rice Lake Weighing Systems distributor
site at
www.rlws.com
The Operator Card included with this manual
provides basic operating instructions for users of the
IQ plus 710. Please leave the Operator Card with the
indicator when installation and conÞguration are
complete.
The IQ plus 710 is NTEP-certiÞed for Classes III and
III L at 10,000 divisions. See Section 10.11 on
page 79 for detailed speciÞcations.
1.1

Operating Modes

The IQ plus 710 has three modes of operation:
Normal mode
Normal mode is the weighing mode of the
indicator. The indicator displays gross, net, or tare
weights as required, using the secondary display
to indicate scale status and the type of weight
value displayed. Once conÞguration is complete
and a legal seal is afÞxed to the back of the
indicator, this is the only mode in which the IQ
plus 710 can operate.
Setup mode
Most of the procedures described in this manual
require the indicator to be in setup mode,
including conÞguration and calibration.
To enter setup mode, remove the large Þllister
head screw from the enclosure backplate. Insert a
screwdriver or a similar tool into the access hole
and press the setup switch once. The indicator
display changes to show the word
Test mode
Test mode provides a number of diagnostic
functions for the IQ plus 710 indicator. Like setup
mode, test mode is entered using the setup switch.
See Section 10.9 on page 76 for more information
about entering and using test mode.
.
.
CONFIG
Introduction
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents