Reporting Commands; Reset Configuration Command; Parameter Setting Commands - Rice Lake 380 Synergy Technical Manual

Digital weight indicator
Table of Contents

Advertisement

380 Synergy Digital Weight Indicator
7.2

Reporting Commands

Reporting commands return specific information to the communications port. The commands listed in
either setup mode or weigh mode.
Command
DUMPALL
Returns a list of all parameter values
AUDIT.LRVERSION
Returns the legally relevant firmware version
VERSION
Returns the firmware version
BUILD
Returns the firmware version and build number
HWSUPPORT
Returns the CPU board part number
HARDWARE
Returns C1 if the RTC Option is installed, or FF if no option is installed
7.3

Reset Configuration Command

The following command can be used to reset the configuration parameters of the 380.
Command
RESETCONFIGURATION
All scale calibration settings are lost when the RESETCONFIGURATION command is run
Note
7.4

Parameter Setting Commands

Parameter setting commands allow the current value for a configuration parameter to be displayed or changed.
Current configuration parameter settings can be displayed in setup mode or weigh mode using the following syntax:
command<ENTER>
Most parameter values can be changed in setup mode only.
Use the following command syntax when changing parameter values: command=value<ENTER>. Use no spaces before or
after the equal (=) sign. If an incorrect command is typed or an invalid value is specified, the indicator returns ?? followed by the
error message.
Example: to set the motion band parameter on Scale #1 to 5 divisions, type the following:
SC.MOTBAND#1=5<ENTER>
To return a list of the available values for parameters, enter the command and equal sign, followed by a question mark
(command=?<ENTER>). The indicator must be in setup mode to use this function.
After changes are made to configuration parameters using EDP commands, use the KSAVE or KSAVEEXIT commands to
commit the changes to memory.
Command
SC.CAPACITY#n
Scale capacity
SC.ZTRKBND#n
Zero track band (in display divisions)
SC.ZRANGE#n
Zero range in % of Full Scale (capacity)
SC.INITIALZERO#n
Initial Zero range in % of full scale
SC.MOTBAND#n
Motion band (in display divisions)
SC.SSTIME#n
Standstill time (in 0.1 second intervals; 10 = 1 second)
SC.OVERLOAD#n
Overload
SC.MAX_WEIGHT#n
Maximum weighment (read only)
SC.NUMWEIGH#n
Number of weighments (read only)
For commands ending with #n, n is the scale number (1)
36
Visit our website
Table 7-2. Reporting Commands
Restores all configuration parameters to default values (setup mode only)
Table 7-3. Reset Configuration Command
Description
Table 7-4. Scales Commands
www.RiceLake.com
Function
Function
Values
0.000001–999999.0, 10000.0 (default)
0.0–100.0, 0.0 (default)
0.0–100.0, 1.9 (default)
0.0–100.0, 0.0 (default)
0–100, 1 (default)
0–600, 10 (default)
FS+2% (default), FS+1D, FS+9D, FS
-999999–999999
0–4294967295
Table 7-2
can be used in
.

Advertisement

Table of Contents
loading