Rice Lake IQ PLUS 710 Installation Manual page 36

Digital weight indicator
Hide thumbs Also See for IQ PLUS 710:
Table of Contents

Advertisement

SETPTS Menu
Parameter
Choices
HYSTER
number
PREACT
OFF
ON
LEARN
PREVAL
number
RELNUM
1–20
BATCH
OFF
ON
PSHACCM
OFF
ON
ONQUIET
PSHPRNT
OFF
ON
WAITSS
PSHTARE
OFF
ON
ALARM
OFF
ON
START
1–20
END
1–20
32
IQ plus 710 Installation Manual
GROSSSP, NETSP, and RELSP setpoint types: Specifies a band around the setpoint
value that must be exceeded before the setpoint, once off, can trip on again.
GROSSSP, NETSP, and RELSP setpoint types: Allows the digital output associated
with a setpoint to shut off before the setpoint is satisfied to allow for material in
suspension.
The ON value adjusts the setpoint trip value up or down (depending on the TRIP
parameter setting) from the setpoint value.
The LEARN value can be used to automatically adjust the preact value after each
batch. LEARN compares the actual weight at standstill to the target setpoint value,
then adjusts the preact by half of the difference after each batch.
GROSSSP, NETSP, and RELSP setpoint types: Specifies the preact value for
setpoints with PREACT set to ON or LEARN. Depending on the TRIP setting
specified for the setpoint, the setpoint trip value is adjusted up or down by the preact
value.
RELSP setpoints: Specifies the number of the relative setpoint. The target weight for
this setpoint is:
• For +RELSP, the value of the relative setpoint plus the value (VALUE parameter) of
this setpoint
• For –RELSP, the value of the relative setpoint minus the value of this setpoint
• For %RELSP, the percentage (specified on the VALUE parameter for this setpoint)
of the relative setpoint
GROSSSP, NETSP, and RELSP setpoint types: Specifies whether the setpoint is
used as a batch (ON) or continuous (OFF) setpoint.
GROSSSP, NETSP, RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify ON
to update the accumulator and perform a print operation when the setpoint is
satisfied. Specify ONQUIET to update the accumulator without printing.
GROSSSP, NETSP, RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify ON
to perform a print operation when the setpoint is satisfied; specify WAITSS to wait for
standstill after setpoint is satisfied before printing.
GROSSSP, NETSP, RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify ON
to perform an acquire tare operation when the setpoint is satisfied. NOTE: PSHTARE
acquires the tare regardless of the value specified for the REGULAT parameter on the
PROGRM menu.
GROSSSP, NETSP, RELSP, DELAY, and WAITSS setpoint types: Specify ON to
display the word ALARM on the primary display while the setpoint is active (batch
setpoints) or while the setpoint is not tripped (continuous setpoints).
TIMER and CONCUR setpoint types: Specifies the starting setpoint number. Do not
specify the number of the TIMER or CONCUR setpoint itself. The TIMER or
CONCUR setpoint begins when the starting setpoint begins.
TIMER and CONCUR setpoint types: Specifies the ending setpoint number. Do not
specify the number of the TIMER or CONCUR setpoint itself. The TIMER or
CONCUR setpoint stops when the ending setpoint begins.
Table 3-7. Setpoint Menu Parameters (Continued)
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents