PROGRM Menu
Parameter
Choices
CONSNUM
0
number
CONSTUP
0
number
UID
0
unit-ID
TARE100
OFF
MODE1
MODE2
MODE3
MODE4
MODE5
MODE6
ACCUM
OFF
ON
CFGPWD
0
1–9999999
SPPWD
0
1–9999999
KYBDLK
OFF
ON
AUXLK
ON
OFF
MACONLY
OFF
ON
ZERONLY
OFF
ON
ALPHAKB
ON
OFF
PROMPTS
PROMPT1–
PROMPT60
MACRO1
STRTBAT
MACRO2
EDIT
MACRO3
MACRO4
Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value is incremented following each print operation that includes <CN> in the ticket
format. When the consecutive number is reset, it is reset to the value specified on the
CONSTUP parameter.
Specifies the consecutive number start-up value used when the consecutive number is reset
by sending the KCLRCN EDP command or a CLRCN digital input. Value specified must be in
the range 0–9 999 999.
Specifies the unit identification number. Value specified can be any alphanumeric value, up to
seven characters.
Specifies the truck mode used. If selected, the indicator switches from normal mode to the
selected truck mode. See Section 7.0 on page 52 for more information about using the truck
modes.
MODE1: Auto clear ID, keyed tares, value swapping
MODE2: Auto clear ID, no keyed tares, value swapping
MODE3: Stored ID, keyed tares, value swapping
MODE4: Stored ID, no keyed tares, value swapping
MODE5: Stored ID, keyed tares, no value swapping
MODE6: Stored ID, no keyed tares, no value swapping
Accumulator. Specifies whether the accumulator is enabled.
Configuration password. Specify a non-zero value to restrict access to all configuration
menus.
Setpoint password. Specify a non-zero value to restrict access to the setpoint menu.
Keyboard lock. Specify ON to disable the keypad in normal mode.
Auxiliary keypad lock. Specify ON to disable all keys except ZERO, GROSS/NET, TARE,
UNITS, and PRINT in normal mode.
Macro keys only. Specify ON to disable all except the four macro keys (F1–F4) in normal mode.
Zero key only. Specify ON to disable all front panel keys except ZERO in normal mode.
Alpha keyboard. Specify ON to enable alpha entry for the indicator keypad. If OFF is specified,
the ALPHA ENTRY key is disabled.
Specify prompts for use in macros and setpoint names. Prompts are referenced by the NAME
parameter under the MACRO and SETPTS submenus; prompts appear in the secondary
display area during macro and setpoint execution.
Specify MACROs 1–4. The STRBAT parameter can be set on to start a batch sequence on
completion of the macro; the EDIT parameter contains up to 30 macro steps, including
simulated keystrokes and pause/release conditions. See Section 9.0 on page 60 for more
information about configuring macros.
Table 3-6. Program Menu Parameters (Continued)
Description
Configuration
25