Rice Lake IQ PLUS 710 Installation Manual page 82

Digital weight indicator
Hide thumbs Also See for IQ PLUS 710:
Table of Contents

Advertisement

¥ When a batch is running, the
keys are locked out and any setpoint value
changes are ignored.
¥ When a batch is paused, all digital outputs are
set off except those associated with PAUSE
setpoints and all continuous setpoint kinds.
¥ When a batch is paused in the middle of a
setpoint, the batch resumes at the beginning of
the setpoint when it is restarted.
Digital Inputs
¥ Digital inputs 1 and 2 have been changed to use
the same default values as the IQ plus 800/810:
DIGIN1=BATSTART; DIGIN2=BATRUN.
¥ Digital input selections now include CLRTAR
(clear tare), CLRACC (clear accumulator),
GROSS, NET, PRIM (primary units), SEC
(secondary units), TIME, and DATE pseudo key
functions.
Macros
¥ MACRO submenu inserted in PROGRM menu
(MACRO1ÐMACRO4 now under the MACRO
submenu).
¥ F1ÐF4 values added to KEYPAD macro
submenu, allowing macros to be looped or
linked.
¥ Pseudokey selections on the PSEUDO macro
submenu now include CLRTAR (clear tare) and
CLRACC (clear accumulator).
¥ Wait for standstill (WAITSS) pause release
capability added to PAUSREL macro submenu.
WAITSS releases when the scale is stable within
the speciÞed motion band.
¥ MOTION pause release function on PAUSREL
submenu changed to release when motion is
detected.
¥ Setpoint compare values expanded to 20
(COMPR1ÐCOMPR20).
78
IQ plus 710 Installation Manual
EDP Commands
and
ZERO
TARE
¥ Except for those commands requiring numeric
¥ KCLRNV EDP command added for clearing
¥ KCLRTAR EDP command added for clearing
¥ KLOCK and KUNLOCK EDP commands
¥ ConÞguration changes made using the EDP
Error Messages and Test Menu
¥ The numeric value returned by the XE command
¥ ECHO R (echo received characters) and XMT U
or text entry, entering any valid EDP command
(while in setup mode) followed by an equal sign
and question mark (
<cmd>=?
values for the command.
nonvolatile RAM.
tare values.
added for locking and unlocking individual front
panel keys.
commands now take effect only when the
indicator leaves setup mode.
now represents only the error conditions present,
if any.
(transmit ÒuÓ characters) functions have been
removed from the TEST menu.
) now lists possible

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents