8.13
Automatic path segmentation
The total traversing distance of 10 mm will be divided into five path sections each of 2 mm
(SPP=2).
Note
The path segments effected by SPP are always equidistant, i.e. all segments are equal in
length. In other words, the programmed path segment size (SPP setting) is valid only if the
quotient of the total traversing distance and the SPP value is an integer. If this is not the
case, the size of the path segment is reduced internally such as to produce an integer
quotient.
Fig. 8-41
Example:
N10 G1 G91 SON X10 Y10
N20 SPP=3.5 X15 Y15
When the total traversing distance is 15 mm and the path segment length 3.5 mm, the quo-
tient is not an integer value (4.28). In this case, the SPP value is reduced down to the next
possible integer quotient. The result in this example would be a path segment length of 3
mm.
Number of SPN path segments
SPN defines the number of path segments to be generated from the total traversing di-
stance. The length of the segments is calculated automatically. Since SPN is non-modal,
punching or nibbling must be activated beforehand with PON or SON respectively.
8-204
Y
Y2
E1
E1
X2
X2/Y2
Programmed traverse path (nibbling or punching block)
E1
Programmed path segment length
E1'
Automatically rounded path segment length
SINUMERIK 802D sl Operation and Programming Nibbling (BP-N), 06/2006 Edition
X
6FC5 398-3CP10-0BA0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents