8.2
Positional data
8.2.10

Programmable working area limitation: G25, G26, WALIMON, WALIMOF

Functionality
The working area limitation defines the working area for all axes. Traversing is allowed in this
area only. The coordinate parameters are machine-based.
To be able to use the working area limitation, it must be activated for the axis concerned.
This is done using the interactive screenform under <Offset Param.> <Setting data> <Wor-
king area limit.>.
There are two possibilities to define the working area:
S Input of the values using the interactive screenform of the control system under <Offset
Param> <Setting data> <Working area limit.>
Thus, the working area limitation is also effective in the JOG mode.
S Programming using G25/G26
The values for the individual axes can be changed in the part program. The values en-
tered in the interactive screenform (<Offset Param.> <Setting data> <Working area li-
mit.>) are overwritten.
The working area limitation is enabled/disabled in the program by WALIMON/WALIMOF.
Programming
G25 X... Y...
G26 X... Y...
WALIMON
WALIMOF
(Machine)
Y
Y
Fig. 8-13
8-148
; Lower working area limitation
; Upper working area limitation
; Working area limitation ON
; Working area limitation OFF
Y1
G26
M
G25
X G25
Programmable working area limitation (example: 2-dimensional)
SINUMERIK 802D sl Operation and Programming Nibbling (BP-N), 06/2006 Edition
Working area
X1
(Machine)
X
G26